Objetivo: Cuantificar e identificar las aerobacterias Staphylococcus sp. presentes en Unidades de Cuidados Intensivos (UCI) del Hospital Universitario Fernando Troconis.
Materiales y método: Se recolectaron muestras en aire por triplicado en dos estaciones monitorizadas en cada una de las tres UCI, utilizando un impactador de cascada de dos etapas ubicado a 1,5 m de altura operando a caudal constante (28,3 l min-1) durante cinco min y provisto con ágares selectivos. Las muestras se incubaron a 37° C durante 48 horas para recuento de colonias e identificación de especies.
Resultados: La máxima concentración de Staphylococcus sp. (412,25 ± 56,3 UFC/m3) correspondió a la estación 1 de la UCI adultos, mientras que el máximo valor promedio fue obtenido en la estación 2 de esta unidad con 287,99 UFC/m3. Las concentraciones mínimas de Staphylococcus sp. se registraron en las UCI pediátrica y neonatal (2,36 ± 1,5 UFC/m3), y el promedio mínimo en la estación 1 de la neonatal (77 UFC/m3). La especie de Staphylococcus más frecuente fue S. haemolyticus sp.
Conclusión: La concentración de Staphylococcus sp. supera la reportada por estudios similares, aumentando la probabilidad de contraer infecciones nosocomiales por aerobacterias al recolectar el 67,12% de aerosoles respirables.
Objective: To establish the concentration and the taxonomic identity of airborne Staphylococcus sp. present in the intensive care unit of an University Hospital.
Materials and methods: Airborne bacteria were collected taking each sample in triplicate in the three intensive care units, using two-stage cascade impactor with selective agar for the sampling and cultivation of bacteria.
The impactor was set up at a height of 1.5 m above floor level, and operating at air-sampling rate of 28,3 l min-1 for five minutes. After sampling the plates were incubated at 37° C for 48 hr and colony forming units on each plate were counted and subsequently done by the taxonomic identification to species level.
Results: The maximum concentration of Staphylococcus sp. reported 412.25 ± 56.3 CFU/m3 in the adult intensive care unit, whereas than the maximum average was 287.99 CFU/m3 in the same intensive care unit.
The minimum concentration was obtained in the pediatric and neonatal intensive care with a value of 2.36 ± 1.5 CFU/m3, and the minimum average reported was 77.00 CFU/m3 in the neonatal intensive care unit. S. haemolyticus was the specie most frequently identified.
Conclusions: The concentration of Staphylococcus sp. exceeds the aerobiological values presented in other studies at hospitals. Besides, increasing the probability of contracting nosocomial infections as result of the exposure to airborne bacteria, reported 67.12% of breathable aerosols.